Atmospheric Forced Draft Evaporator
Where the quantity of wastewater is small and difficult to treat, atmospheric forced draft evaporator is the ideal choice. Various models from 100 to 5000 Liters per day capacities are standard.
Advantages and Features
Working Principle

Atmospheric evaporator consists of Feed Pump, Evaporator Tank with Electrical or Diesel Heater, Circulation Pump, Blower, Mixing tube, Mist Eliminator and Humid air Outlet. The wastewater from the wastewater tank is pumped by the feed Pump to the evaporator tank. Electric or Diesel heater heats the effluent in the evaporator tank. The hot effluent is pumped into the Mixing Tube, through which air is blown from atmosphere by the blower. The air and wastewater are thoroughly mixed in the mixing tube and passes to the evaporator tank, before getting out through the Mist eliminator and humid air outlet. Electrical controls limits the operation of feed pump, circulation pump and blower depends on the levels in the evaporator tank and wastewater tank. Control system with automatic ON/OFF, safety shut off and switch gears with control panel are provided with the system.